Efficacy and safety of appropriate shocks and antitachycardia pacing in transvenous and subcutaneous implantable defibrillators: analysis of all appropriate therapy in …
RE Knops, W Van Der Stuijt, PPHM Delnoy… - Circulation, 2022 - Am Heart Assoc
… for implantable cardioverter defibrillator (ICD) therapy. Patients … unsuccessful in terminating
ventricular arrhythmias, we … of ATP, and a shorter capacitor charge time of the TV-ICD. It is …
ventricular arrhythmias, we … of ATP, and a shorter capacitor charge time of the TV-ICD. It is …
Progressive implantable cardioverter-defibrillator therapies for ventricular tachycardia: The efficacy and safety of multiple bursts, ramps, and low-energy shocks
M Strik, FD Ramirez, N Welte, T Bonnin, S Abu-Alrub… - Heart Rhythm, 2020 - Elsevier
… on optimal implantable cardioverter-defibrillator programming … antitachycardia pacing (ATP)
for the treatment of ventricular … often treated with a burst of ATP before or during charging of …
for the treatment of ventricular … often treated with a burst of ATP before or during charging of …
Novel implantable cardioverter defibrillator programming with high rate cut-off, long detection intervals and multiple anti-tachycardia pacing reduces mortality
AD Schober, AL Schober, U Hubauer… - Circulation …, 2021 - jstage.jst.go.jp
… charging followed by shock therapies. The detection time … ICD therapies to life-threatening
ventricular arrhythmias and to … are still warranted to optimize ICD programming. Randomized …
ventricular arrhythmias and to … are still warranted to optimize ICD programming. Randomized …
Additional antitachycardia pacing programming strategies further reduce unnecessary implantable cardioverter-defibrillator shocks
… used, and 1 ATP sequence during charging in the VF zone. The … the initial therapy at
terminating fast ventricular arrhythmias (75… pacing pulses, must also be considered when …
terminating fast ventricular arrhythmias (75… pacing pulses, must also be considered when …
[HTML][HTML] Automatic adjustment of ventricular antitachycardia pacing and individualized device therapy
R Tripathi, C Gubran, C Jeavons - HeartRhythm Case Reports, 2022 - Elsevier
… of iATP prior to and during charging, followed by full-output (40 … the successful conversion of
ventricular tachycardia to sinus … ramp overdrive pacing for both slow (<188 bpm) and fast VT. …
ventricular tachycardia to sinus … ramp overdrive pacing for both slow (<188 bpm) and fast VT. …
[HTML][HTML] Management of hemodynamically stable wide QRS complex tachycardia in patients with implantable cardioverter defibrillators
FD Regoli, M Cattaneo, F Kola, A Thartori… - Frontiers in …, 2023 - frontiersin.org
… minority also have an implantable cardioverter defibrillator (ICD). … treatment by proposing a
structured approach for the optimal … tested antitachycardia pacing in implantable cardioverter …
structured approach for the optimal … tested antitachycardia pacing in implantable cardioverter …
[HTML][HTML] 2019 HRS/EHRA/APHRS/LAHRS focused update to 2015 expert consensus statement on optimal implantable cardioverter-defibrillator programming and …
MK Stiles, L Fauchier, CA Morillo, BL Wilkoff - Heart Rhythm, 2020 - Elsevier
… tachycardia detection, tachycardia therapy, and defibrillation testing for implantable
cardioverter-defibrillator (ICD) patient treatment… 1 Use of ATP Before/During Charging in the VF …
cardioverter-defibrillator (ICD) patient treatment… 1 Use of ATP Before/During Charging in the VF …
ANTITACHYCARDIA PACING: OPTIMAL PROGRAMMING AND PREDICTION OF EFFICACY FOR THE TREATMENT OF VENTRICULAR ARRHYTHMIAS. STATE OF …
L Avolio, P Zappulla, N Valenti, ML Presti… - Authorea …, 2023 - techrxiv.org
… on optimal implantable cardioverterdefibrillator programming and … the value of a single burst
during charge (DC) programming, … of antitachycardia pacing in fast ventricular arrhythmias in …
during charge (DC) programming, … of antitachycardia pacing in fast ventricular arrhythmias in …
2019 HRS/EHRA/APHRS/LAHRS focused update to 2015 expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing
MK Stiles, L Fauchier, CA Morillo, BL Wilkoff - EP Europace, 2019 - academic.oup.com
… /implantable cardioverter-defibrillator (ICD) therapies where … Use of ATP Before/During
Charging in the VF zone achieves … 30ms) in the Fast VT zone will not prevent therapy but rather …
Charging in the VF zone achieves … 30ms) in the Fast VT zone will not prevent therapy but rather …
Anti-tachycardia Pacing: Mechanism, History and Contemporary Implementation
S Panchangam, KM Monahan, RH Helm - Current Treatment Options in …, 2022 - Springer
… terminated during ICD charging (~ 3.3 s) and prior to shock therapy … of antitachycardia
pacing in fast ventricular arrhythmias in primary prevention implantable cardioverter-defibrillator …
pacing in fast ventricular arrhythmias in primary prevention implantable cardioverter-defibrillator …